No. | Type | Unit | Quantity |
1 | RAY-AAA98I Binary Gradient Pump | set | 1 |
2 | UV98I UV Detector | set | 1 |
3 | Rheodyne 7725i Injector | set | 1 |
4 | C18, 5μm, Amino Acid Column | set | 1 |
5 | Guard Column | set | 1 |
6 | N2000 Work Station | set | 1 |
7 | T98 Column Oven | set | 1 |
8 | Ultrasonic cleaner(3L) | set | 1 |
9 | Solvent Filter | set | 1 |
10 | 0.45μ Organic Filter membrane | piece | 100 |
11 | 0.45μ Water Filter membrane | piece | 100 |
12 | Organic Sample Filter | piece | 100 |
13 | Water Sample Filter | piece | 100 |
14 | Aspirator Vacuum Pump | set | 1 |
15 | Amino Acid Standard Sample | set | 1 |
16 | Amino Acid Derivatives Solvent | set | 1 |
RAY-AAA98I Binary Gradient Pump
Main features:
This configuration is suitable for feed, food , chemical, pharmaceutical and other amino acid analysis, using pre-column derivatization method detachable 21 kinds or 18 kinds of amino acids. Can also be used as a binary HPLC .
Technical parameters:
Gradient Pump: Flow rate 0.001–10 ml/min; Accuracy ±0.2%.
Gradient Accuracy: ≤0.06% (ASTM).
Max Pressure: 9000 psi.
Degassing System: Built-in 4-channel vacuum degasser.
Additional Functions: Auto plunger rod cleaning, anti-salt precipitation.
Sampling: Loop and variable sampling, 1–500 µl injection volume, Reproducibility <1% @10 µl.
Sample Tray: 2 trays, 48 positions each (1.5 ml bottles).
Memory Effect: <0.01%.
Chromatographic Column: Sodium ion exchange (4×150 mm).
Derivatization: Ninhydrin post-column method.
Temperature Control: RT–150°C, 0.1°C increments.
Spectroscopy: Aberration concave diffraction grating, 190–800 nm range.
Environment: 10–30°C, ≤80% RH.
(1) P98-Ⅰ type binary gradient infusion pump
Flow range : 0.01ml / min ~ 15ml / min
Flow rate accuracy : <3μl (0.01ml / min ~ 0.1ml / min), <1% (0.5ml / min ~ 9.99ml / min)
B liquid % Accuracy : = ± 0.5% ABS
Pressure range : 0.00MPa ~ 42MPa (420Kgf / cm2)
Microprocessor controlled proportional valve control encoder disk ; high accuracy.
Imported motor drive imports , subdivision twenty thousand steps, no mechanical noise ; to ensure accuracy.
Imported sealing systems , high pressure capability .
Single- piston reciprocating pump , a single one-way valve design solution without degassing .
Imported high pulsation damper , buffering capacity, so that the minimum ripple .
Multiple time program , do a gradient .
Automatic memory program , easy to bring up the methods.
Display: LCD screen display.
Display mode : the actual pressure , flow rate setting , the pressure lower limit .
Security Control : The pressure limit control , buzzer alarm, automatic shutdown.
Vertical chassis , touch panel.
(2) UV98-Ⅰ variable wavelength UV-Vis detector
Optical system : Imported grating monochromator design , imported photoelectric receiving device .
Light source: deuterium lamp Hamamatsu L6302
Wavelength range : 190 ~ 700nm
Wavelength accuracy : ± 1nm
Wavelength repeatability : ± 0.4nm
Noise : 2.5 × 10-5AU (pp) ( dynamic index , the mobile phase of methanol , 254nm, next column )
Drift : 1 × 10-3AU / hr ( dynamic index , the mobile phase of methanol , 254nm, next column )
Attenuation range : 0.002 ~ 2AU / mV 10 files
Detection cell volume : 4.5μl;
Detection cell voltage : 120 Kgf / cm2 ( patent pool structure design )
Minimum detectable amount : 2 × 10-8g / ml ( naphthalene / methanol solution )
Microprocessor-controlled , automatic scanning of stay ; wavelength repeatability.
LCD screen display, automatically find the wavelength , automatic zero adjustment.
Unique deuterium lamp control , striking voltage make deuterium lamp life up to 2500 hours.
Patented back pressure design, the bubble is not easy to enter the flow cell.
Vertical chassis , touch panel ; simple hydraulic connections .
Main features:
This configuration is suitable for feed, food , chemical, pharmaceutical and other amino acid analysis, using pre-column derivatization method detachable 21 kinds or 18 kinds of amino acids. Also available as two yuan HPLC
1. SPECIFICATION
a. Operating pressure: 0~42MPa (6000 psi) maximum.
b. Flow rate range: 0.1~15ml/min;
c. Flow rate precision: ±1%;
d. Flow rate accuracy: 25ml/368~387s(±3%);
e. Compositional precision:0.5% absolute
f. Pressure solution: 0.1MPa;
g. Over pressure protection: pump shuts off if pressure exceeds limit specified by user-42.0 Mpa
(6000 psi) maximum.
2.Environment
a.Temperature requirements: ambient temperature range 10 to 35℃
b. Operates in relative humidity from 5% to 80%;
c. Power requirements: 220Vac±5%,
d.Power frequency: 50±0.5Hz (voltage and frequency specified on the tag attached to the power cord)
3. GENERAL PARAMETERS
a. Power Supply: 400W;
b. Dimensions: 450mm(D)×210mm(W)×390mm(H);
c. Weight: 20kg;
Wavelength range:190-700nm
Spectral bandwidth:5nm
Wavelength accuracy:±2nm
Wavelength reproducibility:±0.2nm
Absorbance range:
Recorder output:0.002au/mV to 2au/mV in steps of 1, 2, 5
Data system output:2au/V, fixed
Noise:5×10-5au (Peak-Peak)
Test Conditions: Wavelength: 254nm
Mobile phase: methanol
Flow rate: 1ml/min
Time constants: 0.5s
Drift:1×10-3au/hr
Test Conditions: Wavelength: 254nm
Mobile phase: methanol
Flow rate: 1ml/min
Time constants: 0.5s
Flow cell volume:4.5μl
Time constants:0.05s, 0.5s, 5s
Autozero:Yes
2. General Parameters
a. Power Supply: 200W;
b. Dimensions: 450mm(D)×180mm(W)×390mm(H);
c. Weight: 15kg;
Figure 1 18 Amino Acid Stand Sample
1. Asp 2.Glu 3. Ser 4. Gly 5 His 6. Arg 7. Thr 8. Ala 9. Pro 11. Val
12. Met 13. (Cys)2 14. Ile 15. Leu 16. Trp 17. Phe 18. Lys
Copyright © 2021Raylabel
Tel/WhatsApp:0086 13391320338 Email:info@raylabel.com
Address:22F,No.15,Lane 33,Rd Zhongtan,Putuo District,Shanghai,China,200061.